DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 2-38 OFF STOP RUN Special ES2 SA2 Latch Content SS2 SX2 Attrib.
Default D EX2 SE -ed ON RUN STOP D1424* Starting reference for Master to write in Slave ID#10 ○ ○ ○ ○ - - - R/W YES H’10C8 D1425* Starting reference for Master to write in Slave ID#11 ○ ○ ○ ○ - - - R/W YES H’10C8 D1426* Starting reference for Master to write in Slave ID#12 ○ ○ ○ ○ - - - R/W YES H’10C8 D1427* Starting reference for Master to write in Slave ID#13 ○ ○ ○ ○ - - - R/W YES H’10C8 D1428* Starting reference for Master to write in Slave ID#14 ○ ○ ○ ○ - - - R/W YES H’10C8 D1429* Starting reference for Master to write in Slave ID#15 ○ ○ ○ ○ - - - R/W YES H’10C8 D1430* Starting reference for Master to write in Slave ID#16 ○ ○ ○ ○ - - - R/W YES H’10C8 D1431* Times of PLC LINK polling cycle ○ ○ ○ ○ 0 - - R/W NO 0 D1432* Current times of PLC LINK polling cycle ○ ○ ○ ○ 0 - - R/W NO 0 D1433* Number of slave units linked to EASY PLC LINK ○ ○ ○ ○ 0 - - R/W NO 0 D1434* Data length to be read on Slave ID#1 ○ ○ ○ ○ - - - R/W YES 16 D1435* Data length to be read on Slave ID#2 ○ ○ ○ ○ - - - R/W YES 16 D1436* Data length to be read on Slave ID#3 ○ ○ ○ ○ - - - R/W YES 16 D1437* Data length to be read on Slave ID#4 ○ ○ ○ ○ - - - R/W YES 16 D1438* Data length to be read on Slave ID#5 ○ ○ ○ ○ - - - R/W YES 16 D1439* Data length to be read on Slave ID#6 ○ ○ ○ ○ - - - R/W YES 16 D1440* Data length to be read on Slave ID#7 ○ ○ ○ ○ - - - R/W YES 16 D1441* Data length to be read on Slave ID#8 ○ ○ ○ ○ - - - R/W YES 16 D1442* Data length to be read on Slave ID#9 ○ ○ ○ ○ - - - R/W YES 16 D1443* Data length to be read on Slave ID#10 ○ ○ ○ ○ - - - R/W YES 16 D1444* Data length to be read on Slave ID#11 ○ ○ ○ ○ - - - R/W YES 16 D1445* Data length to be read on Slave ID#12 ○ ○ ○ ○ - - - R/W YES 16 D1446* Data length to be read on Slave ID#13 ○ ○ ○ ○ - - - R/W YES 16 D1447* Data length to be read on Slave ID#14 ○ ○ ○ ○ - - - R/W YES 16 D1448* Data length to be read on Slave ID#15 ○ ○ ○ ○ - - - R/W YES 16 D1449* Data length to be read on Slave ID#16 ○ ○ ○ ○ - - - R/W YES 16 D1450* Data length to be written on Slave ID#1 ○ ○ ○ ○ - - - R/W YES 16 D1451* Data length to be written on Slave ID#2 ○ ○ ○ ○ - - - R/W YES 16 D1452* Data length to be written on Slave ID#3 ○ ○ ○ ○ - - - R/W YES 16 D1453* Data length to be written on Slave ID#4 ○ ○ ○ ○ - - - R/W YES 16 D1454* Data length to be written on Slave ID#5 ○ ○ ○ ○ - - - R/W YES 16 D1455* Data length to be written on Slave ID#6 ○ ○ ○ ○ - - - R/W YES 16 D1456* Data length to be written on Slave ID#7 ○ ○ ○ ○ - - - R/W YES 16 D1457* Data length to be written on Slave ID#8 ○ ○ ○ ○ - - - R/W YES 16 D1458* Data length to be written on Slave ID#9 ○ ○ ○ ○ - - - R/W YES 16 D1459* Data length to be written on Slave ID#10 ○ ○ ○ ○ - - - R/W YES 16 D1460* Data length to be written on Slave ID#11 ○ ○ ○ ○ - - - R/W YES 16 D1461* Data length to be written on Slave ID#12 ○ ○ ○ ○ - - - R/W YES 16 D1462* Data length to be written on Slave ID#13 ○ ○ ○ ○ - - - R/W YES 16 D1463* Data length to be written on Slave ID#14 ○ ○ ○ ○ - - - R/W YES 16 D1464* Data length to be written on Slave ID#15 ○ ○ ○ ○ - - - R/W YES 16 D1465* Data length to be written on Slave ID#16 ○ ○ ○ ○ - - - R/W YES 16 D1480* ↓ D1495* The data which is read from slave ID#1 in the PLC LINK at the time when M1353 is OFF ○ ○ ○ ○ 0 - - R NO 0 The initial data register where the data read from slave ID#1~ID#16 in the PLC LINK is stored at the time when M1353 is ON ○ ○ ○ ○ - - - R YES 0 D1496* ↓ D1511* The data which is written into slave ID#1 in the PLC LINK at the time when M1353 is OFF ○ ○ ○ ○ 0 - - R/W NO 0 The initial data register where the data written into slave ID#1~ID#16 in the PLC LINK is stored at the time when M1353 is ON ○ ○ ○ ○ - - - R/W YES 0