Delta DVP-ES2 — 5.5 Types of Sequences

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming SFC diagram of alternative convergence: S30 S40 S50 X0 X1 X2 S60 Example of alternative divergence & alternative convergence: Step Ladder Diagram: SFC Diagram:

M1002 X0 S1 S20 Y0 X1 X4 X7 X2 S30 Y1 X5 S31 Y3 X20 S32 Y5 S40 Y2 S41 Y4 S42 Y6 X3 X6 X21 S50 T1 S60 Y7 X22 S1 5-16 ZRST S0 S127 SET S1 S1 X0 S SET S20 S20 S Y0 X1 SET S30 X4 SET S31 X7 SET S32 S30 S Y1 X2 SET S40 S40 S Y2 X3 SET S50 S31 S Y3 X5 SET S41 S41 S Y4 X6 SET S50 S32 S Y5 X20 SET S42 S42 S Y6 X21 SET S50 S50 S TMR T1 K10 T1 SET S60 S60 S Y7 X22 S1 RET END ZRST S0 S127 SET S1 SET S20 SET S30 SET S31 SET S32 TMR T1 K10 SET S40 SET S50 SET S41 SET S50 SET S42 SET S50 TMR T1 K10 SET S60