Delta DVP-ES2 — C.2 Special Data Register

Appendix C Inforamation about TP Series Text Panels C-7 OFF STOP RUN Special Content Latch    Attrib. Default D -ed ON RUN STOP D1241* When interupt I400/I401/I100/I101 occurs, D1241 stores the high Word of the high-speed counter. 0 0 - R NO 0 D1249 Set value for COM1 (RS-232) data receiving time-out (Unit: 1ms, min. 50ms, value smaller than 50ms will be regarded as 50ms) (only applicable for MODRW/RS instruction) In RS instruction, no time-out setting if “0” is specified. 0 - - R/W NO 0 D1250 COM1 (RS-232) communication error code (only applicable for MODRW/RS instruction) 0 - - R/W NO 0 D1252 Set value for COM3 (RS-485) data receiving time-out (Unit: 1ms, min.

50ms, value smaller than 50ms will be regarded as 50ms) (only applicable for MODRW/RS instruction) In RS instruction, no time-out setting if “0” is specified 0 - - R/W NO 0 D1253 COM3 (RS-485) communication error code (only applicable for MODRW/RS instruction) 0 - - R/W NO 0 D1255* COM3 (RS-485) PLC communication address - - - R/W YES 1 D1256 ↓ D1295 For COM2 RS-485 MODRW instruction. D1256~D1295 store the sent data of MODRW instruction. When MODRW instruction sends out data, the data will be stored in D1256~D1295. Users can check the sent data in these registers. 0 - - R NO 0 D1296 ↓ D1311 For COM2 RS-485 MODRW instruction.

D1296~D1311 store the converted hex data from D1070 ~ D1085 (ASCII). PLC automatically converts the received ASCII data in D1070 ~ D1085 into hex data. 0 - - R NO 0 D1313* Second of RTC: 00 ~ 59 - - - R/W YES 0 D1314* Minute of RTC: 00 ~ 59 - - - R/W YES 0 D1315* Hour of RTC: 00 ~ 23 - - - R/W YES 0 D1316* Day of RTC: 01 ~ 31 - - - R/W YES 1 D1317* Month of RTC: 01 ~ 12 - - - R/W YES 1 D1318* Week of RTC: 1 ~ 7 - - - R/W YES 2/5 D1319* Year of RTC: 00 ~ 99 (A.D.) - - - R/W YES 8/10 D1320 Analog I/O module code 0X22: TP04P-22XA11R/TP70P-22XA11R 0X41: TP04P-21EX11R/TP70P-21EX11R - - - R NO # D1354 PLC Link scan cycle (Unit: 1ms)  Max:

K32000  D1354 = K0 when PLC Link stops or when the first scan is completed 0 0 0 R NO 0 D1355* Starting reference for Master to read from Slave ID#1 - - - R/W YES H’1064 D1356* Starting reference for Master to read from Slave ID#2 - - - R/W YES H’1064 D1357* Starting reference for Master to read from Slave ID#3 - - - R/W YES H’1064 D1358* Starting reference for Master to read from Slave ID#4 - - - R/W YES H’1064 D1359* Starting reference for Master to read from Slave ID#5 - - - R/W YES H’1064