Delta DVP-ES3 — 6.6.3 Connection Test

DVP-ES3 Series Operation Manual (4) After you successfully download the hardware configuration to the CPU module, the BUS FAULT LED indicator on the CPU module is OFF. Close the HWCONFIG window. If the BUS FAULT LED indicator on the CPU module is still ON or blinking, the CPU module is in an abnormal state. Make sure the actual hardware configuration is the same as the hardware configuration in the HWCONFIG window, and refer to the operation manual for more information about eliminating the error. Refer to Chapter 8 for more information about HWCONFIG.  Downloading the program After the program compiles, on the PLC menu point to Transfer , and then click Download .

You can also click on the toolbar after the program compiles. In the Transfer Setup dialog box select the Program checkbox and the Comments checkbox so that you can upload the program in the CPU module later, and then click OK . _6 6.6.3 Connection Test After you download a program to a PLC, you can monitor the execution status of the PLC through ISPSoft. ISPSoft provides two monitoring modes; device monitoring mode and program monitoring mode. *. You can enable the device monitoring function without program monitoring; however, if you enable the program monitoring function, the device monitoring function is also enabled.

6-28 Monitoring mode Description Device monitoring mode You can monitor the status of the devices in the PLC through the monitoring table. In this mode, ISPSoft updates only the status of the devices. The current program in ISPSoft does not have to be the same as the program in the PLC. Program monitoring mode In this mode, the operating status of the program is displayed in the program editing window. The present program in ISPSoft must be the same as the program in the PLC.