Chapter 11 CPU Module Operating Principle 11.1.2 I/O Refreshing and Communication Service Refreshing I/O The CPU module reads external I/O data periodically or outputs data to an external I/O. Refreshing the 11 I/O includes the following. Refreshing data in a digital I/O module Refreshing data in an analog I/O module Refreshing data in a network module All I/O refreshing executes in the same loop. The data in an input device refreshes before a program executes, and the data in an output device refreshes after the program executes. Communication service Communication service is the unscheduled communication service for a network module.
It includes the communication requests sent from external equipment to a CPU module, and the communication requests sent from the CPU module to the external equipment. 11-3 Unit Maximum data exchange Data exchange area Depends on the number of input/output Digital I/O module Input relay/Output relay channels in the unit. Depends on the number of input/output Analog I/O module Data register channels in the unit. Network module Depends on the unit. Data register