Delta DVP-ES3 — 4.6.2.2 Relay Output Circuit

DVP-ES3 Series Operation Manual 2. Transistor output 4.6.2.2 Relay Output Circuit Relay terminals have no polarity. They can be used with alternating current that passes through a load, or with _4 direct current that passes through a load. The maximum current that can pass through every relay terminal is 2 A, and refer to each product specification for the maximum current that can pass through every common terminal. The lifetime of a relay terminal varies with the working voltage, the load type (the power factor cosψ), and the current passing through the terminal. The relation is shown in the life cycle curve below.

3000 2000 0.4) ψ = Operation(X10 ) 3 1000 =0.4) ψ 200 300 500 100 30 50 20 0.5 0.1 0.2 0.3 0.7 1 2 Contact Current(A)  Relay output circuit 4-18 I/O(Sink ) I/O Y0.0 + 5~3 0VDC 0.5A C0 (Sou rce ) C0 + 5~3 0VDC 0.5A Y0.0 12 0VAC Resisti ve e(t=7ms) ctive(cos 30 VDC Inductiv 240VAC Indu 120VAC Inductive 30VDC Inducti ve (t=40 ms)