Delta DVP-ES3 — 6.26.2 Explanation of High-speed Output Instructions

Chapter 6 Applied Instructions Example 1. Taking (40000, 50000) as the center O and (10000, 10000) as point A, draw a circle as shown below. O (40000, 50000) O A A (10000, 10000) 2. Steps:  The calculated relative coordinates of point O: (30000, 40000)  The coordinates of point A is the present position; SR460=10000 and SR480=10000  S 3 =1 and the clockwise circle drawing is performed with a 5 ° as the basic motion angle.  When the PLC runs the program and M0 is set to ON, the relative-position circle drawing starts. 6_ 3. Operation:  When the PLC runs the program and M0 is ON, the PLC starts to draw the circle in the clockwise direction at 100 kHz.

 When the circle drawing completes, SM461 and SM481 are ON. 6-847