Delta DVP-ES3 — 6.26.2 Explanation of High-speed Output Instructions

DVP-ES3 Series Programming Manual _6 Symbol S 1 : Relative target position A S 2 : Relative target position B S 3 : Target speed S 4 : Target speed ratio adjusted value (floating point value) D 1 : Pulse output device D 2 : Target speed can change indicator Explanation 1. This high speed output instruction specifies a movement going back and forth between two target positions that are converted from the two relative target positions specified by S 1 and S 2 . This instruction is applicable for machines such as warping machines in the textile industry, and winding & binding machines in the cable industry. 2.

When the instruction starts the output, the relative positions S 1 and S 2 must be specified first so that the instruction can make the calculation for switching to the next output. After the instruction is executed, you can modify the target positions to execute, but you cannot change the outputting target positions. 6-860 API Instruction Operand Description 2723 D PPGB S1,S2,S3,S4,D1,D2 Point-to-point go back and forth Device X Y M S T C HC D FR SM SR E K 16# “$” F S1  S2  S3  S4  D1  D2  BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type S1   S2   S3   S4  D1  D2  Pulse Instruction 16-bit instruction 32-bit instruction - - ES3