Delta DVP-ES3 — 6.8.2 Explanation of Miscellaneous Instructions

DVP-ES3 Series Programming Manual Example 1 1. The instruction multiplies the time for which the button switch M0 has been turned ON by n, and stores the product in D0. You can use the button switch (ON) to record the time. 2. When M0 is switched OFF, the value in D0 is unchanged. _6 Additional remarks 1. If D +1 exceeds the device range, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#2003. 2. If the value in n is not between 0 – 2, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#200B. 3. If you declare the operand D in ISPSoft, the data type is ARRAY [2] of WORD/INT. 6-182 M0 X0.0 M0 X0.0