DVP-ES3 Series Programming Manual _2 2-34 Latched Attribute Default OFF STOP RUN SM Function ON RUN STOP SM1346 UDP socket 3 data sending OFF – – N R OFF SM1347 UDP socket 3 connection closed ON – – Y R ON SM1348 UDP socket 3─Error flag OFF – – N R OFF SM1349 UDP socket 4 connection started OFF – – N R OFF SM1350 UDP socket 4 data receiving OFF – – N R OFF SM1351 UDP socket 4 data sending OFF – – N R OFF SM1352 UDP socket 4 connection closed ON – – Y R ON SM1353 UDP socket 4─Error flag OFF – – N R OFF SM1440 Error in I/O connection 1 through EtherNet/IP (Adapter) OFF - - N R OFF SM1441 Error in I/O connection 2 through EtherNet/IP (Adapter) OFF - - N R OFF SM1442 Error in I/O connection 3 through EtherNet/IP (Adapter) OFF - - N R OFF SM1443 Error in I/O connection 4 through EtherNet/IP (Adapter) OFF - - N R OFF SM1444 Error in I/O connection 5 through EtherNet/IP (Adapter) OFF - - N R OFF SM1445 Error in I/O connection 6 through EtherNet/IP (Adapter) OFF - - N R OFF SM1446 Error in I/O connection 7 through EtherNet/IP (Adapter) OFF - - N R OFF SM1447 Error in I/O connection 8 through EtherNet/IP (Adapter) OFF - - N R OFF *SM1448 I/O connection 1 is established through EtherNet/IP (Adapter) OFF - - N R OFF *SM1449 I/O connection 2 is established through EtherNet/IP (Adapter) OFF - - N R OFF *SM1450 I/O connection 3 is established through EtherNet/IP (Adapter) OFF - - N R OFF *SM1451 I/O connection 4 is established through EtherNet/IP (Adapter) OFF - - N R OFF *SM1452 I/O connection 5 is established through EtherNet/IP (Adapter) OFF - - N R OFF *SM1453 I/O connection 6 is established through EtherNet/IP (Adapter) OFF - - N R OFF *SM1454 I/O connection 7 is established through EtherNet/IP (Adapter) OFF - - N R OFF *SM1455 I/O connection 8 is established through EtherNet/IP (Adapter) OFF - - N R OFF SM1581 Refresh and then release the control over the connection of Delta servo CAN axis 1 OFF OFF – N R/W OFF SM1582 Refresh and then release the control over the connection of Delta servo CAN axis 2 OFF OFF – N R/W OFF SM1583 Refresh and then release the control over the connection of Delta servo CAN axis 3 OFF OFF – N R/W OFF SM1584 Refresh and then release the control over the connection of Delta servo CAN axis 4 OFF OFF – N R/W OFF SM1585 Refresh and then release the control over the connection of Delta servo CAN axis 5 OFF OFF – N R/W OFF SM1586 Refresh and then release the control over the connection of Delta servo CAN axis 6 OFF OFF – N R/W OFF SM1587 Refresh and then release the control over the connection of Delta servo CAN axis 7 OFF OFF – N R/W OFF