DVP-ES3 Series Programming Manual _6 Symbol m 1 : CPU module number or the remote extension module number m 2 : Order numbers of the extension number m 3 : Control register number S : Device where the data is stored D : Device where the error code is stored n : Data length Explanation 1. This instruction writes data to the control register in an extension module. 2. The value in m 1 must be 0. If the value in m 1 is NOT 0, it will be seen as 0. 3.
The operand m 2 represents the number of the right-side special extension modules (digital I/O module excluded) 6-414 API Instruction code Operand Function 1401 D TO P m1, m2, m3, S, D, n Writing data into the control register in an extension module Device X Y M S T C HC D FR SM SR E K 16# “$” F m1 m2 m3 S D n BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type m1 m2 m3 S D n Pulse instruction 16-bit instruction 32-bit instruction ES3 ES3 ES3