Delta DVP-ES3 — 6.17.2 Explanation of Real-time Clock Instructions

DVP-ES3 Series Programming Manual 6. When using on-line editing, reset the conditional contact to initialize the instruction. Example When M0 is ON, the instruction timer starts to count. When the time for which M0 has been ON reaches 100 hours, M10 is ON. The current time is recorded in D0, and the current time which is less than one hour is recorded in D1. D2 is for system use. The value in it cannot be altered; otherwise, an error occurs. Additional remarks 1. When S is less than or equal to 0, the instruction is not executed, and the state of the output device is unchanged. 2. If the value in D 1 is less than 0 , the state of the output device is unchanged. 3.

If D 1 +2 exceeds the device range, an operation error occurs, the instruction is not executed, SM0 is ON, and the _6 error code in SR0 is 16#2003. 4. If you declare the operand D 1 in ISPSoft, the data type is ARRAY [3] of WORD/INT. 6-486