Delta DVP-ES3 — 6.20.2 Explanation of Other Instructions

DVP-ES3 Series Programming Manual Example Suppose the value in D0 is 0. When M0 is ON for the first time, the instruction transmits the data in E0–E9 to D1–D10 and increments the value in D0 to 1. When M0 switches from OFF to ON for the second time, the instruction transmits the data in E0–E9 to D17–D26, and increments the value in D0 to 2. When M0 switches from OFF to ON for the n th time, the instruction transmits the data in E0–E9 to (n*16)+1–(n*16)+10. Additional remarks 1. If the value in D is not between 0–99, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#2003. _6 2.

If the range of devices is not sufficient for D +((the value in D )+1)*16-1), the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#2003. 6-620