DVP-ES3 Series Programming Manual b15 b0 b7 b8 b15 b0 b7 b8 S1+1 S1 D+1 D S1+2 S1+3 D+2 D+3 S1+4 After the instruction is executed D+4 S1+5 S2 S2+1 S3 4 Number of characters which are replaced S4 6 Character which is replaced 3. If the string in S 2 is 16#00, the instruction deletes the matching characters. 4. If the value in S 3 is larger than the number of characters that the instruction can replace in the string in S 1 , the instruction replaces the characters in S 1 starting from the character indicated by the value in S 4 to the last character in S 1 . 5. If the value in S 3 is equal to 0, the instruction is not executed.
Example _6 When M0 is ON, the data in D0–D7 is “1234ABAB1234AB”, and the data in D10–D11 is “CDEF”. When the $RPLC instruction executes, the instruction replaces the characters in D0–D7 starting from the character indicated by the value in D51 with the characters in D10–D11. The number of characters to replace is indicated by the value in D50, and the instruction stores the result in D20–D27. 6-670 16#32(2) 16#31(1) 16#34(4) 16#33(3) 16#36(6) 16#35(5) 16#38(8) 16#37(7) 16#30(0) 16#39(9) Ignored 16#00 16#32(2) 16#31(1) 16#34(4) 16#33(3) 16#4D(M) 16#35(5) 16#30(0) 16#4E(N) 16#0000 16#4E(N) 16#4D(M) Ignored 16#00