Delta DVP-ES3 — 6.21.2 Explanation of String Processing Instructions

Chapter 6 Applied Instructions 2. Starting contact is M0 3. The quantity of split strings D200=4 4. The split strings are as below. 6_ 3 rd set: D120~D129 are occupied; D120~D121=“5.67” 6-683 Device Value String D6 16#3736 “76” D7 16#382C “8,” D8 16#3139 “19” D9 16#3330 “30” D10 16#453B “e;” D11 16#4644 “fd” 1st set: D100~D109 are D100 D101 D102 D103 D104 D105 D106 D107 D108 D109 occupied; D100-D101=“abcd” HEX 6261 6463 0000 0000 0000 0000 0000 0000 0000 0000 String “ba” “dc” 16#0000 - - - - - - - 2nd set:

D110~D119 are D110 D111 D112 D113 D114 D115 D116 D117 D118 D119 occupied; D110~D111=“1234” HEX 3231 3433 0000 0000 0000 0000 0000 0000 0000 0000 String “21” “43” 16#0000 - - - - - - - Device D120 D121 D122 D123 D124 D125 D126 D127 D128 D129 HEX 2E35 3736 0000 0000 0000 0000 0000 0000 0000 0000 String “.5” “76” 16#0000 - - - - - - -