Delta DVP-ES3 — 6.22.2 Explanation of Ethernet Instructions

DVP-ES3 Series Programming Manual Symbol S : Source value D : Conversion result Explanation 1. This instruction converts the string IP address in S into an integer IP address, and stores the conversion result in D and D +1. 2. The operand S occupies eight consecutive devices. "192 .16 8. 0.1 " S+0 S+1 S+2 S+3 Af ter t he inst ruct ion is e xecut ed D+0 S+4 D+1 S+5 S+6 S+7 3. There are 1–3 characters in every section of the string IP address in S . These sections are separated by “.” (16#2E). For example, you can enter “192.168.0.1” instead of “192.168.000.001”. 4. The value of each section of the string IP address in S must be between 0–255.

6-706 API Instruction code Operand Function 2207 IATON P S,D Converting a string IP address into an integer IP address Device X Y M S T C HC D FR SM SR E K 16# “$” F S    D  BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type S     D    Pulse instruction 16-bit instruction 32-bit instruction ES3 ES3 - 6 _ " 9" " 1" ". " " 2" " 6" " 1" ". " " 8" " 0" " 0" ". " " 0" " 0" " 0" 1 6 #00 " 1" 16 #C0(19 2) 16# A8(168 ) 1 6# 00 (0) 1 6#0 1 (0 1)