Delta DVP-ES3 — 6.26.2 Explanation of High-speed Output Instructions

Chapter 6 Applied Instructions 5. The execution sequence is based on the value of the low 16-bit code in the table above, and described below. 6_  The direction of DOG signal is determined by the value of bit 5.  The DOG signal is determined by the value of bit 4.  Mode 0 or mode 1 for the zero point return, selected according to the value of bit 3.  The operation of the zero point return is performed according to the values of bit 1 and bit 0.  The operation of the clear signal specified by bit 2 is performed. 6. Set the input point and the rising edge trigger condition in HWCONFIG, when the position control system needs positive and negative limit input points.

Note that the limit input points must not be the same as the zero point or Z phase input points. 7. The Completion flag is set to ON after the instruction finishes performing the specified function. For example, for function code 6, the PLC sets the Completion flag to ON only when the Z phase seeking completes. 8. After the DZRN instruction is executed, an interrupt service program is not executed till the DZRN instruction is program.

disabled, if the specified input point for the zero point is the same as that for the external input interrupt in the 6-781 Mode 1 outputs the number of pulses after returning to the zero point Number of pulses for motion 8+2=10 (bit 3=ON) The operation for zero point return is the same as that for low 16-bit code 1. After returning to the zero point, the motion continues in accordance with the number of specified pulses. When the value of the high 16-bit code is a positive number, the motion is in the positive direction. A negative number indicates that the motion is in the negative direction.

Mode 1 Searches for Z phase after returning to the zero point (Z phase input point is set in HWCONFIG ) Number of Z phases 8+3=11 (bit 3=ON) The operation for zero point return is the same as that for low 16-bit code 1. After returning to the zero point, the motion continues in accordance with the number of Z phases to seek. When the value of the high 16-bit code is a positive number, the motion is in the positive direction. A negative number indicates that the motion is in the negative direction. If the rising edge trigger for X1 is the condition for Z phase input, counting is performed once when the rising-edge trigger for X1 occurs.

Mode 1 Outputs the clear signal after returning to the zero point (Output clear point is set in HWCONFIG ) 0 or number of pulses or number of Z phases 12–15 (bit 3=bit 2 =ON) After returning to the zero point in mode 1, the 20ms-width clear signal is output. DOG point is B point +16 (bit 4=ON) When in the low 16-bit code, bit 4 is ON, it means the zero point is ON as the DOG point changes from ON to OFF and the zero point is left as the DOG point changes from OFF to ON.