Chapter 6 Applied Instructions Function code 0+ the negative limit function enabling: You set the negative limit input point in HWCONFIG, and then download the setting to the PLC. The PLC automatically calculates the negative limit function when the instruction is executed. DZRN function is executed and the search for the zero point is in the negative direction with the target frequency. After the negative limit switch is ON, the motion stops and then goes in the positive direction after reversing direction. The motion continues in the positive direction after leaving the negative limit switch. The output frequency ramps down after receiving the DOG signal.
The reverse output is performed with the JOG frequency after reversing direction. The output stops when the signal changes from ON to OFF after the axis moves away from the DOG signal. Negative direction Negative direction Positive direction ON Completion flag Negative limit switch DOG signal ON Frequency Target frequency 6_ JOG frequency Time 1 2 3 4 5 Example 1 direction. When the DOG signal is received and X4 is ON, it keeps moving in the negative directon with the JOG When M0 is ON, outputting the pulse from Y0 with a frequency of 20 kHz to search for the zero point in the negative frequency of 1 kHz. The output stops immediately after X4 changes from ON to OFF. 6-785