Delta DVP — 13.2 TRD/TZCP - Control of Warehouse Automatic Door

13 . Real Time Calendar Time Design Examples Control Program: Time zone compare the set time with the read current time DVP-PLC Application Examples 13-4 M1000 MOV K7 D10 Set the lower l MOV K30 D11 warehouse op hours as 7:30 MOV K0 D12 MOV K22 D20 Set the upper MOV K30 D21 warehouse op hours as 22:3 MOV K0 D22 M1000 Read the RTC of PLC and TRD D0 in D0~D6.

D4~D6 store H TZCP D10 D20 D4 M10 M11 SET Y0 SET Y2 Y0 X4 AM7:30~PM10:30, RST Y0 opening action until Y2 X6 RST Y2 M10 SET Y1 M12 SET Y3 PM10:30~AM7:30, Y1 X5 closing action until t RST Y1 Y3 X7 RST Y3 X0 Press door 1 manual ope SET Y0 be opening until the uppe X1 Press door 1 manual clos SET Y1 be closing until the lower X2 Press door 2 manual ope SET Y2 be opening until the uppe X3 Press door 2 manual ope SET Y3 be closing until the lower SET Y3 MOV K7 D10 MOV K30 D11 MOV K0 D12 MOV K22 D20 MOV K30 D21 MOV K0 D22 TRD D0 TZCP D10 D20 D4 M10 SET Y0 SET Y2 RST Y0 RST Y2 SET Y1 SET Y3 RST Y1 RST Y3 SET Y0 SET Y1 SET Y2