Mitsubishi — Chapter 6 Application Instructions API 00-49

6 Application Instructions API 00-49 groups of 32-bit data and bringing forth the quotient and remainder. If users want to store the quotient of a 32-bit division (leave out the remainder), they have to use AP I115 DIV32/DIV32P. Please refer to the explanation of API 115 DIV32/DIV32P for more information. Program Example: When X0 = On, D0 will be divided by D10 and the quotient will be stored in D20 and remainder in D21. On/Off of the highest bit indicates the positive/negative status of the result value. X0 DVP-PLC Application Manual 6-42 DIV D0 D10 D20 DIV D0 D10 K4Y0