Mitsubishi — Chapter 7 Application Instructions API 50-88

7 Application Instructions API 50-99 13. The complete program: X10 M0 Frequency Number of pulses Output point 14. During the execution of DHSZ instruction, do not modify the set values in the comparison table. 15. The designated data will be arranged into the the above program diagram when the program executes to END instruction. Therefore, PLSY instruction has to be executed after DHSZ instruction has been executed once. DVP-PLC APPLICATION MANUAL 7-24 0 DMOVP K5000 D2 DMOVP K10000 D6 DMOVP K15000 D10 DMOVP K6000 D14 DMOVP K0 D18 DMOVP K0 D0 DMOVP K100 D4 DMOVP K200 D8 DMOVP K300 D12 DMOVP K400 D16 DHSZ D0 K5 C251 M1152 PLS M0 DPLSY D1152 K0 Y0