Mitsubishi — Chapter 8 Application Instructions API 100-149

9 Application Instructions API 150-199  2 nd shift: Assume t2 = 11kHz, internal frequency = 2kHz, gap time = 20ms Ramp-up steps of 2 nd shift: Freq. 1kHz t2=11kHz 2kHz 2kHz t1=6kHz Time 20ms 20ms 20ms g2=40ms  3 rd shift: Assume t3 = 3kHz, gap frequency = 2kHz, gap time = 20ms Ramp-down steps of 3 rd shift: Freq. Change to t3 t2=11kHz 2kHz t3=3kHz Time 20ms 20ms 20ms 20ms Start to change g3=60ms  For program examples please refer to API 199 Points to note: 1. Associated flags: M1029: CH0 pulse output execution is completed M1030: CH1 pulse output execution is completed M1036: CH2 pulse output execution is completed M1037: CH3 pulse output execution is completed M1538:

Indicating pause status of CH0 M1539: Indicating pause status of CH1 M1540: Indicating pause status of CH2 M1541: Indicating pause status of CH0 DVP-PLC Application Manual 9-142