10 Application Instructions API 202-313 Operands: D : Destination device to be reset n: Device specifying the bit to be reset Explanations: 1. EH2/SV_V1.9 and versions above, and EH3/SV2 supports the function. EH series does not support the dunction. 2. Available range for the value in operand n : K0~K15 for 16-bit instruction; K0~K31 for 32-bit instruction. 3. When BRST instruction executes, the output device specified by operand n will be reset (OFF). Program Example: X0 Instruction: Operation:
LD X0 Load NO contact X0 BRST K 4 Y0 D0 When D0 = k1, Y1 is OFF Y2 = OFF When D0 = k2, DVP-PLC Application Manual 10-23 API Mnemonic Operands Function 268 D BRST Reset Specified Bit of a Word Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F BRST: 5 steps DBRST: 9 steps D * * * * * * n * * * * * * * * * * * PULSE 16-bit 32-bit SA SX SC EH SV EH3 SV2 ES EX SS SA SX SC EH3 ES EX SS SA SX SC EH3 ES EX SS EH SV EH SV SV2 SV2 BRST K4Y0 D0