Mitsubishi — 2.10 Special Auxiliary Relays and Special Data Registers

2 Functions of Devices in DVP-PLC DVP-PLC Application Manual 2-65 ES SA Off STOP RUN EH2 EH3 Special D Function EX SX    Attribute Latched Default SV SV2 SS SC On RUN STOP D1340 EH2/SV/EH3/SV2: start/end frequency of the 1st group pulse output CH0 (Y0, Y1) ╳ ○ ○ ○ - - - R/W YES 200 SC: start/end frequency of Y10 output ╳ 200 NO D1341 Low word of max. output frequency Fixed as 200k Hz ╳ ╳ ○ ○ - - - R YES H’04D0 D1342 High word of max. output frequency ╳ ╳ ○ ○ - - - R YES 3 D1343* EH2/SV/EH3/SV2: acceleration/deceleration time for the 1st group pulse output CH0 (Y0, Y1) ╳ ○ ○ ○ - - - R/W YES 100 SC:

acceleration/deceleration time of Y10 output ╳ 200 NO 200 D1344 Low word of the number of compensation pulses of the 1st group pulses CH0 (Y0, Y1) ╳ ╳ ○ ○ - - - R/W YES 0 D1345 High word of the number of compensation pulses of the 1st group pulses CH0 (Y0, Y1) ╳ ╳ ○ ○ - - - R/W YES 0 D1346 Low word of the number of compensation pulses of the 2nd group pulses CH1 (Y2, Y3) ╳ ╳ ○ ○ - - - R/W YES 0 D1347 High word of the number of compensation pulses of the 2nd group pulses CH1 (Y2, Y3) ╳ ╳ ○ ○ - - - R/W YES 0 D1348 SC: low word of present value of Y10 pulse output ╳ ○ ╳ ╳ 0 - - R NO 0 EH2/SV/EH3/SV2: CH0 pulse output.

When M1534 = On, it refers to the deceleration time ╳ ╳ ○ ○ - - - R/W YES 100 D1349 SC: high word of present value of Y10 pulse output ╳ ○ ╳ ╳ 0 - - R NO 0 EH2/SV/EH3/SV2: CH1 pulse output. When M1535 = On, it refers to the deceleration time ╳ ╳ ○ ○ - - - R/W YES 100 D1350 SC: low word of present value of Y11 pulse output ╳ ○ ╳ ╳ 0 - - R NO 0 EH2/SV/EH3/SV2: CH2 pulse output. When M1536 = On, it refers to the deceleration time ╳ ╳ ○ ○ - - - R/W YES 100 D1351 SC: high word of present value of Y11 pulse output ╳ ○ ╳ ╳ 0 - - R NO 0 EH2/SV/EH3/SV2: CH3 pulse output. When M1537 = On, it refers to the deceleration time ╳ ╳ ○ ○ - - - R/W YES 100 D1352 SC:

start/end frequency of Y11 output ╳ ○ ╳ ╳ 200 - - R/W NO 200 EH2/SV/EH3/SV2: start/end frequency of the 2nd group pulse output CH1 (Y2, Y3) ╳ ╳ ○ ○ - - - R/W YES 200 D1353* SC: acceleration/deceleration time of Y11 output ╳ ○ ╳ ╳ 200 - - R/W NO 200 EH2/SV/EH3/SV2: acceleration/deceleration time of the 2nd group pulse output CH1 (Y2, Y3) ╳ ╳ ○ ○ - - - R/W YES 100 D1354 Scan cycle for the PLC link (unit: 1ms) PS1: The maximum value is K32000 PS2: K0: The PLC link stops or the first detection is complete.

╳ ╳ ╳ ○ 0 0 0 R NO 0 D1355* Starting reference for Master to read from Salve ID#1 ╳ ○ ○ ○ - - - R/W YES H’1064 D1356* Starting reference for Master to read from Salve ID#2 ╳ ○ ○ ○ - - - R/W YES H’1064 D1357* Starting reference for Master to read from Salve ID#3 ╳ ○ ○ ○ - - - R/W YES H’1064 D1358* Starting reference for Master to read from Salve ID#4 ╳ ○ ○ ○ - - - R/W YES H’1064 D1359* Starting reference for Master to read from Salve ID#5 ╳ ○ ○ ○ - - - R/W YES H’1064 D1360* Starting reference for Master to read from Salve ID#6 ╳ ○ ○ ○ - - - R/W YES H’1064 D1361* Starting reference for Master to read from Salve ID#7 ╳ ○ ○ ○ - - - R/W YES H’1064 D1362* Starting reference for Master to read from Salve ID#8 ╳ ○ ○ ○ - - - R/W YES H’1064 D1363* Starting reference for Master to read from Salve ID#9 ╳ ○ ○ ○ - - - R/W YES H’1064