DVS Series Managed Industrial Ethernet Switches User’s Manual 3-110 Description Factory Default Logging auto-save-logs Specify whether log messages can be saved in a flash memory automatically: Enable: Log messages can be saved in a flash memory automatically. The saving time depends on the Logging time-range setting. Disable: Log messages can’t be saved in a flash memory automatically. Enable Logging buffered Specify the number of log messages that can be displayed on the Show System Logs page. Enter a number in the range of 1 to 200. The default setting is 50 log messages. 50 Logging time-range (min) Specify the time-range to save the log automatically.
It only works when Logging auto-save-logs function is enabled. Enter a value in the range of 60 to 43200. The default value is 60. 60 Logging manual-save-logs Click the button to save logs in a flash memory manually. None Severity Specify the level of severity that determines which events are logged. A log records messages equal to or above a configured severity threshold. For example, if you select an error, the logged messages include error (3), critical (2), alert (1), and emergency (0). The default level of severity is critical (2). Make a selection from the drop-down list: emergency: The highest warning level (level 0).
An emergency message is saved if the switch is down or not functioning correctly. alert: The second-highest warning level (level 1). An alert message is saved if there is a serious switch malfunction, for example, an important switch function goes down. Action needs to be taken immediately. critical: The third-highest warning level (level 2). A critical message is saved if a critical switch malfunction occurs, for example, two interfaces stop functioning while the rest of the interfaces remain functional. error: The level that indicates that a device error has occurred (level 3), such as an interface going offline. warning: The lowest level of a device warning (level 4). notice:
Normal but significant conditions (level 5). Provides the network administrators with switch information. Informational: Provides switch information (level 6). debug: Provides detailed information about the switch (level 7). This level generates a lot of messages. critical Logging filesize Specify the size of the system file in which the log files are saved. Enter a file size between 1024 and 102400 bytes. Note: The debug log file is not controlled by the size of the system file. The debug log file is a temporary file that is not stored in flash memory. The file can always store the most recent 100 debug log messages, and each debug log message is less than 80 bytes in length. 10240