DVS Series Managed Industrial Ethernet Switches User’s Manual Port Events 3-114 Description Factory Default Authentication Failure Specify whether send alarm email when authentication failure. Checked Dot1d Bridge New Root Specify whether to send an alarm email when a new node is added to the 802.1d network. Checked Dot1d Bridge Topology Changed Specify whether to send alarm email when the 802.1d bridge topology is changed. Checked LLDP Remote Tables Change Specify whether to send an alarm email when the LLDP remote table is changed. Checked Configuration-Changed Specify whether to send an alarm email when the configuration is changed.
Checked Firmware Update Specify whether to send an alarm email when the firmware has been updated. Checked IP Changed Specify whether to send alarm email when the IP address has changed. Checked Password Changed Specify whether to send alarm email when the password has changed. Checked Description Factory Default Port This field displays the interface number. interface number Link-ON Specify whether to send an alarm email when the Link is ON. Checked Link-OFF Specify whether to send an alarm email when the Link is OFF. Checked DDM Failure Specify whether to send an alarm email when the DDM failure event is detected.
Checked Description Factory Default Overload Specify whether to send an alarm email when the traffic of the port is overloaded. If the box is selected, you can configure the Threshold (%) and Duration (s) fields. Unchecked