DVS Series Managed Industrial Ethernet Switches User’s Manual B-4 Address Offset Data Type Description 0x00A0 1 word DI 1 Status 0x0000: OFF 0x0001: ON 0x00A1 1 word DI 2 Status 0x0000: OFF 0x0001: ON Port Information 0x1000 ~ 0x1009 1 word Port 1 to 10 Status 0x0000: Link down 0x0001: Link up 0x0002: Disable 0x1100 ~ 0x1109 1 word Port 1 to 10 Communication Format 0x0000: 10M,Half 0x0001: 10M,Full 0x0002: 100M,Half 0x0003: 100M,Full 0x0004: 1G,Full 0x1200 ~ 0x1209 1 word Port 1 to 10 Flow Control 0x0000: OFF 0x0001: ON 0x1300 ~ 0x1309 1 word Port 1 to 10 MDI/MDIX Setting 0x0000: Auto 0x0001: MDI 0x0002: MDIX 0x1400 ~ 0x14C7 20 words Port 1 to 10 Description EX:
10/100/1000TX,RJ45 Word 0 Hi byte = '1' Word 0 Lo byte = '0' Word 1 Hi byte = '/' Word 1 Lo byte = '1' Word 2 Hi byte = '0' Word 2 Lo byte = '0' Word 3 Hi byte = '/' Word 3 Lo byte = '1' Word 4 Hi byte = '0' Word 4 Lo byte = '0' Word 5 Hi byte = '0' Word 5 Lo byte = 'T' Word 6 Hi byte = 'X' Word 6 Lo byte = ',' Word 7 Hi byte = 'R' Word 7 Lo byte = 'J' Word 8 Hi byte = '4' Word 8 Lo byte = '5' Word 9 Hi byte = '\0' Word 9 Lo byte = '\0' 0x1500 ~ 0x1509 1 word Port 1 to 10 bandwidth overload 0x0000: OFF 0x0001: Port X bandwidth overload