E298GB — Руководство по эксплуатации электронной системы Kuhnke E298GB (EN)

Display control 4.1.3. Character and cursor attributes Character attribute assignment Hex 1Bh 5Eh ATTR AP Decimal 27 94 ATTR AP ASCII ESC ^ ATTR AP With this command, individual character attrtibutes can be as- signed. All characters after this command are noted with this attribute until a new attribute command alters the current char- acter attribute. The command does not affect characters which are on the screen already. The parameter ATTR AP can take on the following values: ATTR AP Function 0 Reset of all attributes 2 Activate flashing 3 Deactivate flashing 4 Activate inverse 5 Deactivate inverse the following are possible only with KDT 635:

8 Activate underlining 9 Deactivate underlining 4 - 9