sinee — EA350 User Manual (EN)

Technical Manual for EA350 Analog Pulse Type Servo Driver V101 Parameter functions: Sets first-order low-pass filtering time constant of AI1 and AI2 analog input respectively. Performs first-order low-pass filtering on the analog input from AI1 and AI2 to reduce analog fluctuation arising from external electromagnetic interference and delay vibration caused by analog mutation. However, a value too big will slow system response.

179 Unit ms Time of taking effect With immediate effect Setting range 0~10000 Data size 16bit Control mode P S T P6-26 AI2 filtering time Initial value 10 Communication address 061AH Unit ms Time of taking effect With immediate effect Setting range 0~10000 Data size 16bit Control mode P S T