sinee — EA350 User Manual

Technical Manual for EA350 Analog Pulse Type Servo Driver V101 Caution ☞ 1: Make sure the setting command of the master per se is 0 V (an impossible value in practice) before performing zero drift self-correction. 2: Zero drift self-correction applies only to scenarios where external setting falls in -10 to 10V. 3: If the actual voltage of the AI terminal exceeds ±2 V during correction, the alarm will be raised. 57 0 Press the key to display , without any operation 1 If AI1 external voltage source is set as 0V (an impossible value in practice), press to display and carry out zero drift self-learning, upon which the result will be saved into P6-33 automatically.

2 If AI2 external voltage source is set as 0V (an impossible value in practice), press to display and carry out zero drift self-learning, upon which the result will be saved into P6-34 automatically.