QUICK GUIDE AND APPLIANCES LIST 13/176 J6 J2 J1 J3 Front view EWM1000 J3-1 Drain pump (line) J3-2 Solenoids (line) J3-3 (line) J3-4 Drain pump (triac) J3-5 Pre-wash solenoid (triac) J3-6 Washing solenoid (triac) J3-7 Solenoids (line) J3-8 (Not used) J1-1 Motor (triac) J1-2 Motor (stator – full range) J1-3 Motor (stator - 1/2 range) J1-4 Motor (rotor) J1-5 Motor (rotor) 1.9 Connectors on circuit board EWM1000 Rear view J2-1 Door safety interlock (line-sensing) J2-2 1st level(sensing) J2-3 (Anti-overflow pressure switch) J2-4 Door safety interlock (triac) J2-5 (Door safety interlock) J2-6 (Anti-overflow pressure switch) J6-1: Heating element (relay) J6-2:
Door safety interlock (line) J8-1 line J8-2 line (neutral) J8 J6 J2 J1 J3 J4 J5 J7 J6-1: Heating element (relay) J6-2:
Door safety interlock (line) J2-1 Door safety interlock (line-sensing) J2-2 1st level(sensing) J2-3 (Anti-overflow pressure switch) J2-4 Door safety interlock (triac) J2-5 (Door safety interlock) J2-6 (Anti-overflow pressure switch) J1-1 Motor (triac) J1-2 Motor (stator – full range) J1-3 Motor (stator - 1/2 range) J1-4 Motor (rotor) J1-5 Motor (rotor) J3-1 Drain pump (line) J3-2 Solenoids (line) J3-3 (line) J3-4 Drain pump (triac) J3-5 Pre-wash solenoid (triac) J3-6 Washing solenoid (triac) J3-7 Solenoids (line) J3-8 (Not used) J4-1 “Door closed” pilot lamp J4-2 “Door closed” pilot lamp J5-1 NTC temperature sensor J5-2 NTC temperature sensor J5-3 Motor (tachymetric generator) J5-4 Motor (tachymetric generator) J5-5 (DSP drum positioning system) Serial interface:
J7-1 ASY IN _ J7-2 ASY OUT _ J7-3 5V J7-4 GND J8 J8-1 line J8-2 line (neutral) Rear view