In case of burning on the main circuit board, check that the problem is not caused by another electrical component (short-circuits, poor insulation, water leakage). Refer to the figures below in order to identify the component that might have caused the burning according to the position of the burned area. The circuit board shown below is the version with the greatest number of components: other boards may not feature all these components. QUICK GUIDE AND APPLIANCES LIST 599 72 40-80 EWM1000plus EWM2000evo EWM3000new 2.16 Burning on the circuit board EWM1000plus 1. Power supply 2. Heating element 3. Door lock pilot lamp 4. Motor 5. Drain pump 6. Door safety interlock 1. Power supply 2.
Heating element 3. Door lock pilot lamp 4. Motor 5. Drain pump 6. Door safety interlock 7. Water fill solenoids 8. Washing NTC temperature sensor 9. Tachometric generator (motor) 10. Drum positioning DSP (top-loader) 11. Mechanical pressure switch 12. User interface communication