electrolux — Electrolux Washing Machines Service Manual: Arched Structural Characteristics, Electrical Components, and Accessibility

5.4.2.1 "Door open" conditions The main PCB, before sending the door aperture signals, checks for the following conditions: The drum must be stationary (no signal from the tachymetric generator) The water level must not be higher than the lower edge of the door The temperature of the water must not be higher than 40є C. 5.4.2.2 Automatic release device In the event of a power failure, or if the appliance is switched off using the ON/OFF switch, or if there is a fault in the solenoid valve, the bi-metal PTC cools within a period of between 55 seconds and about 4 minutes (at a temperature of 65°C), thus releasing the door.

5.4.2.3 Protective cut-out for solenoid valve A PTC, connected in series to the solenoid valve, serves as a current limiter (i.e. overheating cut-out) in the following cases: If the triac on the main PCB is short-circuited If the START/PAUSE button is pressed repeatedly (more than 10 times) 5.4.3 Electrical symbol 5.4.4 Circuit diagram 1. Main switch 2. Solenoid valve 3. PTC protective solenoid valve cut-out 4. Bi-metal PTC 5. Connector SOI/DT 2006-03 dmm 36/70 599 37 67-82