electrolux — Electrolux Washing Machines Service Manual: Arched Structural Characteristics, Electrical Components, and Accessibility

5.15 Circulation pump (if featured) 5.15.1 General characteristics Jetsystem models are fitted with a synchronous circulation pump which continuously circulates the water from the filter body into the tub through the bellows seal. 5.15.2 Electrical symbol 5.15.3 Checking for efficiency NO RE-CIRCULATION - POOR WASHING RESULTS 1. Check that the impeller is not jammed and check for slippage. 2. Check the resistance of the stator winding, which should be approximately 150/200 Ω . Important! If caused to run empty (i.e. disconnected from the hydraulic circuit), synchronous pumps may fail to start up.

This is because, due to their structural characteristics, they require a counter-torque on the impeller to allow the rotor to turn in one direction or the other. For this reason, the pumps should be tested only when fitted to the appliance and after introducing a certain quantity of water. SOI/DT 2006-03 dmm 52/70 599 37 67-82