electrolux ITRONIC LL 60cm — Ami Pro - 336296EN.SAM

TROUBLESHOOTING CHECKING THE EFFICIENCY OF THE COMPONENTS In order to facilitate checking of the efficiency of the component to be tested, a special CONTROL PROCEDURE has been created. The contacts to which the tester should be applied and the correct resistance for the component are shown in the table below. PROCEDURE: Apply the probes of the tester to the points indicated and measure the resistance. After detaching the modular wiring connector fitted to the base of the appliance, measure the resistance to verify the efficiency of the components fitted to the dishwasher. N.B.:

If the resistance measured across contacts 1-8 and 3-8 of the motor is the same ( 28 ohms approx.), this means that the capacitor is short-circuited. The remaining components can be tested in the same way. The measurements can also be made directly on the component or on the modular connections of the control board. The test points and correct values are shown in the table below.

24 COMPONENT TESTER PROBES CONNECTION COLOUR CORRECT VALUE MOTOR (DRAIN) 1 - 8 Blue / Black 73 Ω= ± 7% MOTOR (WASHING) 3 - 8 Orange / Black 48 Ω= ± 7% REGENERATION SOLENOID 4 - 8 Brown / Black 2620 Ω= ± 8% FILL SOLENOID AND ANTI-FLOODING DEVICE 5 - 8 Grey / Black 3950 Ω= ± 8% RESET SOLENOID 6 - 8 White / Black 5200 Ω= ± 8% COMPONENT PROBES CONNECTION CORRECT VALUE POWER CABLE & ON/OFF SWITCH L - C4 N - A1 Key pressed 0 ohms Key pressed 0 ohms DOOR MICROSWITCH C3 - C4 Door closed 0 ohms PRESSURE SWITCH E1 - F7 "EMPTY" (1-2) INFINITE "FULL" (1-3) 0 ohms HEATING ELEM.

& SAFETY THERMOSTAT A2 - C3 2300 W 25 ohms=± 8% INTEGRATED DISPENSER C1 - C2 1300 ohms= ±8% TEMPERATURE SENSOR E2 - E3 At 20 ºC 60.545 ohms ±8% At 65 ºC 9.135 ohms ±8% SALT SENSOR E4 - E5 With salt INFINITE Without salt 0 ohms