Tests to be performed: Is the door correctly closed? NO Close the door correctly and restart the diagnostic cycle to check for further alarm conditions. YES Detach the connectors and effect measurement on the component (fig. 9): - across connectors 3 and 5 the circuit must not be open (the resistive value should be measurable). - across connectors 4 and 5, the circuit must be open (the numbers are printed on the component). Is the door safety interlock is OK? Replace the door interlock and restart the diagnostic cycle to check for further alarm conditions. NO NO YES Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions.
NO Replace the door latch or the door. NO Replace the circuit board and restart the diagnostic cycle to check for further alarm conditions. 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 30/59 599 70 32-47 E41: Door open E41 E41 Maximum time exceeded (PTC = 15 seconds) To check the wiring (with the door open), measure the following wiring connectors: -between wires J1-3 and J1-1, the circuit must NOT be open (measure the resistive value of the PTC). - between wires J1-3 and J1-2, the circuit must be OPEN. Is the door locking device securely anchored to the latch? YES Replace the door locking device. Does the appliance function correctly?
YES Restart the diagnostic cycle to check for further alarm conditions.