Tests to be performed: Replace the belt/pulley and restart the diagnostic cycle to check for further alarm conditions. Replace the positioning sensor and restart the diagnostic cycle to check for further alarm conditions. YES Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. If there are traces of burning on the circuit board, refer to page 59 fig. 18 fig. 19 fig. 20 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 52/59 599 70 32-47 EA1: Drum positioning system (DSP) faulty (top-loaders) EA1 EA1 No signal or discontinuous signal from the sensor for more than 10 seconds during actioning of the motor to position the drum Is the drive belt OK?
Is the pulley OK? Is the ferrite plate positioned correctly? (fig. 20) NO Re YES Remove the connector and measure directly on the sensor: - circuit closed when on the normal section of the pulley (fig.18) - circuit open when on the ferrite plate (fig.19). Is the sensor efficient? NO Re rest Replace the connector and measure across J12-1 and J12-3 on the wiring connector: when the drum is rotated, the circuit should open and close. Check for leakage to ground across the same terminals. Is the wiring OK? NO Che YES Start the diagnostic cycle (phase 9). If alarm EA1 reappears, replace the circuit board and restart the diagnostic cycle to check for further alarm conditions.
0/∞Ω Circuit board ∞ Ω 0/∞Ω 0/∞Ω