Tests to be performed: Tests to be performed: Important! The appliance remains in alarm mode until the frequency returns to the correct value or the appliance is switched off (programme selector on “0”). Only the family of the alarm is displayed, and the diagnostic cycle cannot be started. The complete alarm can be read only when the alarm condition has ceased. Replace the circuit board and restart the diagnostic cycle to check for further alarm conditions. Tests to be performed: circuit board, refer to page 59 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 54/59 599 70 32-47 EH1: Incorrect mains frequency EH1 EH1 The power supply frequency is not within the configured limits Important!

The appliance remains in alarm mode until the frequency returns to the correct value or the appliance is switched off (programme selector on “0”). Only the family of the alarm is displayed, and the diagnostic cycle cannot be started. The complete alarm can be read only when the alarm condition has ceased. Is there interference in the power line, or is the mains frequency outside the correct limits? NO YES Have the user check and if necessary repair the domestic power supply circuit. EH2: Mains voltage too high EH2 EH2 Mains voltage higher than configured voltage (for more than 10 seconds) Is there interference in the power line, or is the mains voltage outside the correct limits?

NO YES Have the user check and if necessary repair the domestic power supply circuit EH3: Mains voltage too low EH3 EH3 Mains voltage lower than configured voltage Important! The appliance remains in alarm mode until the frequency returns to the correct value or the appliance is switched off (programme selector on “0”). Only the family of the alarm is displayed, and the diagnostic cycle cannot be started. The complete alarm can be read only when the alarm condition has ceased. Is there interference in the power line, or is the mains voltage outside the correct limits? NO YES Have the user check and if necessary repair the domestic power supply circuit.