Position 10 Position 11 Position 12ч16 (*) In most cases, the established time is sufficient to check the heating. However, the time can be increased by repeating the phase without draining the water: pass for a moment to a different phase of the diagnostic cycle and then back to the heating control phase (if the temperature is higher than 80°C, heating does not take place). (**) The check at the maximum speed occurs without control of the A.G.S. (Unbalancing Control Algorithm) and no garments must be inside the appliance. A.D.L. 10 / 2010 11/26 599 73 54-08 Drum position Purpose of the test: To check the correct position of the drum via DSP Components activated: • Drum motor.
• Door safety interlock. • Drum position sensor DSP Working conditions: • Door closed LCD display Reading/Deleting the last alarm Purpose of the test: Reading/Deleting the last alarm Components activated: ----- Working conditions: ----- LCD display Displays any alarms present or stored User interface test Purpose of the test: To test operation of all the LEDs and switches. Components activated: • The LEDs are turned on in sequence, as are the symbol groups of the LCD display and its backlight. Behaviour: • All LEDs turn on in sequence. • When a button is pressed, the corresponding group of icon lights up. • The code is shown on the LCD and a beep sounds. • All the icons on the LCD flash.
Working conditions: There is a control to run the test (always active). LCD display