Position 3 Position 4 Position 5 Position 6 A.D.L. 10 / 2010 9/26 599 73 54-08 Water fill to pre-wash compartment Purpose of the test: To check the correct operation of the pre-wash compartment water route. Components activated: • Door safety interlock • Pre-wash solenoid Working conditions: • Door closed • Water level below anti-flooding level • Maximum time 5 mins. LCD display Water level in the tub is displayed (mm) Water fill to conditioner compartment Purpose of the test: To check the correct operation of the conditioner compartment water route. Components activated: • Door safety interlock • Pre-wash and wash solenoid valves Working conditions: • Door closed.
• Water level below anti-flooding level • Maximum time 5 mins. LCD display Water level in the tub is displayed (mm) Water fill to third solenoid valve (steam valve only in certain models) Purpose of the test: To check the correct operation of the steam valve only in certain models) Components activated: • Door fastening device • Third solenoid valve Working conditions: • Door closed • Water level below anti-flooding level • Maximum time 5 mins. LCD display Water level in the tub is displayed (mm) Water fill to fourth solenoid valve Hot water (only in certain models) Purpose of the test: To check the correct operation of the water fill fourth solenoid valve, Hot water (only in certain models.
Components activated: • Door safety interlock • Fourth solenoid valve (where featured) Working conditions: • Door closed • Water level below anti-flooding level • Maximum time 5 mins. LCD display Water level in the tub is displayed (mm)