kendrion — Electromagnetic Vibrating Systems (EN)

Inline Vibrator OMW The magnetic body of the inline vibrator with the excitation winding is fixed to a base. Mounted above is the armature plate, with pole faces separated by an air gap and parallel with those of the magnetic body. Fields of Application Shaking e.g. shaking of punching and stamping waste The armature plate and the base are connected by leaf springs mounted at an angle. If an alternating current is applied to the excitation coil an alternating magnetic field is generated the force of which attracts the ar- mature plate. In the case of type OMW 516004 this electromagnetic force interferes with the force of the permanent magnets used. Feeding e.g.

container filling in the packaging and pharmaceutical industry The frequency of the resulting force corresponds to the frequency of the AC-voltage applied which moves the armature in the same rhythm. Due to the leaf springs mounted at an angle the armature plate performs an arc-shaped vibratory movement.

Dosing Particle feeding for measuring devices and analysis Accessories Advantages •• Phase Angle Control 33 43303B00 / 33 43304B00 •• Infinitely adjustable •• Bellow (serves to cover and protect the OMW) •• Pre-finished system •• Sturdy, compact design •• Leaf springs available as spare parts for all variants Cross Section 1 = Conveying direction 2 = Mounting thread for conveyor channel 3 = Useful side 4 = Armature plate 5 = Leaf spring 6 = Excitation system 7 = Fixing hole 8 = Fixing side (free side) 9 = Connecting cable or flat plug 12