Technician Handbook ! 673 Electronic & Computer Controlled Systems Scaling/Offset Controls Scale Control. Increase to magnify the waveform; decrease to reduce it. The vertical axis rescales accordingly so that you can always read the correct voltage from the axis. Click the reset button (back arrow) to return to a scale of 1.0. The scaling button always shows the selected scale. Offset Control. Increase to move the waveform up the display, decrease to move it down. The vertical axis shifts accordingly so that you can always read the correct voltage from the axis. Adjusting this control is equivalent to clicking and dragging the vertical axis.

Click the reset button (back arrow) to return to an offset of 0.00%. Delay Control (for reference waveforms only). Increase to move the waveform to the left relative to the timing reference point, decrease to move it to the right. Click the reset button (back arrow) to return to a delay of 0 s. The location of the timing reference point depends on which trigger mode PicoScope is in. If the trigger mode is None then the delay is measured relative to the left-hand edge of the display. In all other trigger modes, the delay is measured relative to the trigger marker. Send to back. Draws the channel behind all others. Use if the channel is obscuring another channel of interest. Bring to front.

Draws the channel in front of all others. Use if the channel is hidden behind another. Technical Training 191