Technician Handbook ! 673 Electronic & Computer Controlled Systems Converting Measurements to Amps An inductive clamp actually measures magnetic field strength, not current flow. Therefore when an inductive clamp is used with a DVOM, the meter is set to measure voltage. Most amp clamps have a switch to set the clamp for high or low sensitivity appropriate to the current being measured. The switch is labeled with a millivolts-to-amps ratio needed to convert the DVOM millivolts reading into amps. Different clamps may express conversion factors differently: • 10mV / 1A and 100mV / 1A are based on common units of 1 amp. • 1mV / 100mA and 1mV / 10mA are based on common units of 1mV.

When expressed in common units of 1 amp, the conversion formula is: mV measured A = 100mV (or 10mV, depending on scale) When expressed in common units of 1 mV, the conversion formula is: mA = mV measured X 100 mA (or 10 mA, depending on scale) Technical Training 69