Technician Handbook ! 673 Electronic & Computer Controlled Systems Diagnosing Motor Faults The PicoScope and many other oscilloscopes have amp clamps available as optional equipment. One of the applications of an amp clamp and oscilloscope is in diagnosing motor faults. with an Oscilloscope One of the problems with motors on the verge of failure is they exhibit intermittent faults. Resistance in windings or contacts may fluctuate for an extended period before degrading to the point of complete failure. These fluctuations are not revealed in typical DVOM readings.
An oscilloscope’s high speed measurements, however, can detect fluctuations in current caused by internal variations in motor resistance. Comparing the current signal pattern to a known good vehicle can reveal if a motor is starting to fail. NOTE With many oscilloscopes, using an amp clamp does not require converting millivolts to amps. The oscilloscope can be set to apply the correct conversion factor and display the result in amps. 72 Technical Training