Technician Handbook ! 673 Electronic & Computer Controlled Systems PicoScope View Menu Add View – Add a view of the selected type. In automatic grid layout mode (the default), PicoScope rearranges the grid to make room for the new view, up to a limit of four views. Any further views will be added as tabs in existing viewports. If you have selected a fixed grid layout, PicoScope will not change it. Channels – Select which channels are visible in the current view. X-Axis – Select any suitable channel to drive the X axis. By default, the X axis represents time. If you select an input channel instead, the scope view will become an XY view that plots one input against another.
A quicker way to create an XY view is to use the Add View command (see above). Grid Layout – The grid layout defaults to "Automatic" mode, in which PicoScope automatically arranges views in a grid. You can also select one of the standard grid layouts or create a custom layout, which PicoScope will preserve as you add or remove views. Arrange Grid Layout – Adjust the grid layout to fit the number of views. Reset View Sizes – If you have resized any of the views by dragging the vertical or horizontal separator bars between viewports, this option resets all the viewports to their original sizes. Move View To – Move a view to a specified viewport.
You can achieve the same effect by dragging the view by its name tab and dropping it in a new viewport. (See How to Move a View.) Arrange views – If multiple views are stacked in the same viewport, move them into their own viewports. Technical Training 85