User Manual EM303B General Purpose Inverter RES ESC DATA ENTER RES ESC RES ESC DATA ENTER Flashing RES ESC Flashing Flashing Quickly Flashing RES ESC 闪烁 DATA ENTER RES ESC RES ESC Figure 4-6 Procedures of Saving and Resetting Parameter Flashing Flashing Quickly Flashing Saving Parameters of Relevant Function Code Because there are correlations between some parameters, the relevant parameters will be edited and saved when corresponding function code has been edited and saved. The function codes which have correlations: 1.
Maximum frequency (F0-16) The frequencies related to inverter’s operation and saving the maximum frequency, if the other relevant frequencies > the maximum frequency, inverter will limit the relevant frequency as the maximum frequency. If they are less than the maximum frequency, the relevant frequencies remain unchanged. The function codes are correlative with each other: F0-07 Primary numeric setting frequency setting, F0-17 upper limit frequency, F0-18 lower limit frequency, and F3-00~F3-14 Preset speed setting. 2. Customer defined V/F curve setting The function code of customer defined V/F curve setting: Fd-05~Fd-08, the correlation of them: 0≤Fd-05≤Fd-06≤Fd-07≤Fd-08≤F1-04. 3.
Upper/Lower limit frequency (F0-17, F0-18) F0-17(Upper Limit Frequency)≥F0-18(Lower Limit Frequency) 4. Skip frequencies (F6-16, F6-18, F6-20) F6-16≤F6-18≤F6-20 45 RES ESC