User Manual EM303B General Purpose Inverter 6.2.7 C0 Group: Parameters of Monitoring Function 63 Regulation No. Function Range Unit Default Type S/N Integral Time of VVF Excitation Current Regulation 0.00~600.00 mS 0.00 ● 181 F5-21 Positive/Negative Torque Control 0: Positive/Negative Torque Permitted 1: Negative Torque Prohibited 0 〇 182 F5-22 Positive/Negative Torque Deadband Time 0.00~600.00 S 0.00 〇 183 F5-23 F5-24 Current Loop Gain ACR P _ 0.00~10.00 % 0.40 ● 184 Current Loop Integration ACR Ti _ 0.00~300.00 mS 10.00 ● 185 F5-25 Closed-loop Slip Compensation Gain 50.00~200.00 % 100.00 ● 186 F5-26 Control Mode at Zero Frequency 0: Brake 2 〇 187 F5-27 1: Normal 2:
No output F5-28 Low Frequency Excitation Gain 50.00~150.00 % 100.00 〇 188 Excitation Gain Kd 100.00~600.00 0~9kW % 100.00 ● 189 9~30kW 150.00 30~55kW 200.00 F5-29 55~75kW 300.00 75~110kW 400.00 110~400kW 500.00 Set-up Time of Excitation Gain 0.00~10.00 0~9kW S 0.10 〇 190 F5-30 9~55kW 0.15 55~400kW 0.20 F5-31 Maximum Torque 50.00~250.00 % 100.00 〇 191 No.
Function Range Unit Default Type S/N C0-00 Output Frequency 0.00~Fup/0.0~Fup Hz × 512 C0-01 513 C0-02 Input Frequency Torque Upper Limit Frequency 0.00~Fmax/0.0~Fmax Hz × 514 C0-03 515 C0-04 Synchronous Frequency 0.00~Fup/0.0~Fup Hz × 516 C0-05 517 C0-06 Not Used 518 C0-07 Not Used 519 C0-08 EstimatedFeedback Frequency 0.00~Fup/0.0~Fup Hz × 520 C0-09 521 C0-10 Estimated Slip Frequency 0.00~Fup/0.0~Fup Hz × 522