User Manual EM303B General Purpose Inverter 7.1.3 F7 Group: Advanced Parameters of Operation 68 Upper Limit Frequency of Wobbulation Lower Limit Frequency of Wobbulation~Fmax Hz 40.00 ● 219 F6-27 Lower Limit Frequency of Wobbulation 0.00/0.0~Upper Limit Frequency of Wobbulation Hz 20.00 ● 220 F6-28 Jump Frequency of Wobbulation 0.00/0.0~(Upper Limit Frequency of Wobbulation - Lower Limit Frequency of Wobbulation)/2 Hz 5.00 ● 221 F6-29 No. Function Range Unit Default Type S/N Rising Time of Wobbulation 0.00~600.00 S/min 15.00 ● 222 F6-30 Dropping Time of Wobbulation 0.00~600.00 S/min 5.00 ● 223 F6-31 No.

Function Range Unit Default Type S/N Overload Pre-Alarm Control Ones place: Overload pre-alarm detection 0: Detect all the time 1: Detect at constant speed Tens place: inverter status after pre-alarming 0: Alarm on, run continuously 1: Delayed stop after alarm 00 〇 224 F7-00 Overload Pre-Alarm Detection Time 0.00~60.00 S 5.00 〇 225 F7-01 Overload Pre-Alarm Detection Scale 0.00~600d.00 % 200.00 〇 226 F7-02 Overload Pre-Alarm Stop Delay Time 0.00~600.00 S 5.00 〇 227 F7-03 Analog ADT Options 0: VS 0.00~100.00% 1: IS 0.00~100.00% 2: VF 0.00~100.00% 3:

IF 0.00~100.00% 2 〇 228 F7-04 F7-05 Analog ADT1 0.00~100.00 % 20.00 ● 229 Analog ADT1 Hysteresis 0.00~100.00 (Monotonic decreasing is active) % 5.00 ● 230 F7-06 F7-07 Analog ADT2 0.00~100.00 % 50.00 ● 231 Analog ADT2 Hysteresis 0.00~100.00 (Monotonic decreasing is active) % 5.00 ● 232 F7-08 F7-09 Analog ADT3 0.00~100.00 % 80.00 ● 233 Analog ADT3 Hysteresis 0.00~100.00 (Monotonic decreasing is active) % 5.00 ● 234 F7-10 F7-11 Jog M0 Output Lower Limit 0.00~100.00 % 0.00 ● 235 F7-12 Jog M0 Output Upper Limit 0.00~100.00 % 100.00 ● 236 F7-13 Jog M0 Output Gain 0.00~300.00 % 95.00 ● 237