sinee — EM303B User Manual

User Manual EM303B General Purpose Inverter terminal is on, then the function of PID regulator conducts positive/negative function switch. Its function is equivalent to adjusting parameters of F4-05. Xi=38~43 Not used Xi=44 Preset current limit terminal 1 Xi=45 Preset current limit terminal 2 Xi=46 Preset current limit terminal 3 When selecting preset current limit, 3 input terminals can be defined as the preset current limit terminals. Preset current limits set in FA-07 ~ FA-13 are selected correspondingly through programming these 3 terminals. See Table 7-2 for correlation between preset current limits and the corresponding terminals.

Table 7-2 Correlation between preset current limit and the corresponding terminals Xi=47 Start wobbulation operation Wobbulation operation mode starts. Xi=48 Not used Xi=49 Program operation reset When program operation (PLC) is enabled, if the input signal of this terminal is on, then the program operation time is cleared, and program operation starts from preset speed 1. Xi=50 Alternate motor switching command During running, if input signal of the terminal is on, the inverter regulates the output according to the parameters of Motor 2. Xi=51 External fault input During running, after the terminal receives external device fault signal, inverter stops and enters fault status.

The default is set as NC input by FE-01(Terminal positive/ negative logic). 99 Preset Torque Current Corresponding Torque Terminal 3 Terminal 2 Terminal 1 Setting Current Code OFF OFF OFF Non-preset Current Limit Defined by FC-08 OFF OFF ON Preset Current Limit 1 FA-07 OFF ON OFF Preset Current Limit 2 FA-08 OFF ON ON Preset Current Limit 3 FA-09 ON OFF OFF Preset Current Limit 4 FA-10 ON OFF ON Preset Current Limit 5 FA-11 ON ON OFF Preset Current Limit 6 FA-12 ON ON ON Preset Current Limit 7 FA-13 No.

Function Range Unit Default Type F2-12 Multi-function Output Terminal Y1 See Table7-3 Functions of Numeric Multi-function Output Terminals 0 〇 F2-13 Multi-function Output Terminal Y2 1 〇 Relay Output Terminal R1 9 〇 F2-14