EM500 Open-Loop Vector Control Inverter User Manual 101 F08.05 Preset Speed 6 0.00 - Maximum Frequency F00.16 Hz 25.00 ● F08.06 Preset Speed 7 0.00 - Maximum Frequency F00.16 Hz 30.00 ● F08.07 Preset Speed 8 0.00 - Maximum Frequency F00.16 Hz 35.00 ● F08.08 Preset Speed 9 0.00 - Maximum Frequency F00.16 Hz 40.00 ● F08.09 Preset Speed 10 0.00 - Maximum Frequency F00.16 Hz 45.00 ● F08.10 Preset Speed 11 0.00 - Maximum Frequency F00.16 Hz 50.00 ● F08.11 Preset Speed 12 0.00 - Maximum Frequency F00.16 Hz 50.00 ● F08.12 Preset Speed 13 0.00 - Maximum Frequency F00.16 Hz 50.00 ● F08.13 Preset Speed 14 0.00 - Maximum Frequency F00.16 Hz 50.00 ● F08.14 Preset Speed 15 0.00 - Maximum Frequency F00.16 Hz 50.00 ● F08.15 Simple PLC Running Mode 0:
Stop after Single Running 1: Stop after Limited Times of Cycles 2. Run at Last Preset Speed after Limited Times of Cycles 3: Continuous Cycle 0 ● F08.16 Limited Times of Cycles 1 - 10000 1 ● F08.17 Simple PLC Memory Ones Place: Stop Memory 0: Disabled (Start from Preset Speed 1) 1: Enabled (Start at Power Failure) Tens Place: Power Failure Memory 0: Disabled (Start from Preset Speed 1) 1: Enabled (Start at Power Failure) 0 ● F08.18 Simple PLC Time Unit 0: s 1: min 0 ● F08.19 Setting of Preset Speed 1 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2:
Acceleration/Deceleration Time 3 3: Acceleration/Deceleration Time 4 0 ● F08.20 Running Time of Preset Speed 1 0.0 - 6000.0 5.0 ● F08.21 Setting of Preset Speed 2 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration 0 ●